Leave Your Message

Oil resistance festoon cable with PE/PUR/PVC Insulation

Flexible flat cables as the mobile connections are very suitable for dry or wet indoor or outdoor electrical installations, such as lifting machinery, crane, hoisting machinery, port machinery and so on.

    Technical Date​

    Specification(mm2)

    Overall diameter(mm)

    Approx weight(kg/m)

    Tensile  Load(N)

    Current at 30℃(A)

    Max. resistance of the Current at 30℃(Ω/KW)

    3*1.5

    13.6*5.4

    0.139 

    76 

    16

    13.83

    4*1.5

    16.2*5.4

    0.171 

    102 

    16 

    13.83

    5*1.2

    20.5*5.4

    0.215 

    127 

    16 

    13.83

    6*1.5

    22.4*5.4

    0.241 

    152 

    16 

    13.83

    7*1.5

    25.3*5.4

    0.275 

    178 

    16 

    13.83

    8*1.5

    29.2*5.4

    0.316 

    203 

    16 

    13.83

    9*1.5

    33.5*5.5

    0.361 

    228 

    16 

    13.83

    10*1.5

    35.5*5.4

    0.388 

    254 

    16 

    13.83

    12*1.5

    41*5.4

    0.453 

    305 

    16 

    13.83

    16*1.5

    56.6*5.4

    0.619 

    406 

    16 

    13.83

    18*1.5

    63*5.4

    0.691 

    457 

    16

    13.83

    24*1.5

    82.5*5.4

    0.909 

    609 

    16 

    13.83

    3*2.5

    16*6.5

    0.206 

    127 

    25 

    8.295

    4*2.5

    18*6.5

    0.243 

    170 

    25 

    8.295

    5*2.5

    23.2*6.5

    0.310 

    212 

    25 

    8.295

    6*2.5

    27*6.5

    0.364 

    254 

    25 

    8.295

    7*2.5

    31.7*6.5

    0.427 

    297 

    25 

    8.295

    8*2.5

    36*6.5

    0.485 

    339 

    25 

    8.295

    9*2.5

    39.8*6.5

    0.539 

    382 

    25 

    8.295

    10*2.5

    41.7*6.5

    0.576 

    424 

    25 

    8.295

    12*2.5

    53*6.5

    0.719 

    509 

    25 

    8.295

    16*2.5

    65.8*6.5

    0.912 

    679 

    25 

    8.295

    18*2.5

    79.2*6.5

    1.075 

    763 

    25 

    8.295

    24*2.5

    99.8*6.5

    1.379 

    1018 

    25 

    8.295

    Cable Structure​

    1. Conductor: Oxygen free copper/tinned copper/others, with VDE0295 class 6 standard

    2. Insulation: PUR/PE/NBR/PVC…etc optional

    3. Outer Sheath: high standard PUR/PVC/NBR…etc material

    Electrical Performance​​

    Voltage: 0.6/1kv customized

    Test Voltage: 3.5kv/5min (AC)

    Bending Radius & Temperature Range​​

    Fixed Installation:5 * cable outer diameter

    Mobile Installation:6-10 * cable outer diameter

    Temperature Range :-15 ℃ ~ 70℃

    description2