0.6/1kv foil shielded Medium voltage festoon cable
Technical Date
Specification(mm2) |
Overall diameter(mm) |
Approx weight(kg/m) |
Tensile Load(N) |
Current at 30℃(A) |
Max. resistance of the Current at 30℃(Ω/KW) |
3*185+1*95 |
115*30.8 |
9.064 |
13259 |
430 |
0.11 |
3*240+1*120 |
125.6*35.5 |
11.603 |
17137 |
535 |
0.0833 |
3*10+2*6 |
45*10 |
0.878 |
857 |
65 |
1.985 |
3*16+2*10 |
47*11.3 |
1.170 |
1387 |
90 |
1.258 |
3*25+2*16 |
57.2*13.2 |
1.721 |
2182 |
120 |
0.811 |
3*35+2*16 |
62.9*15.2 |
2.184 |
2794 |
155 |
0.576 |
3*50+2*25 |
75.2*17.6 |
3.098 |
4078 |
175 |
0.401 |
3*70+2*35 |
84.2*19.6 |
4.071 |
5712 |
220 |
0.283 |
3*95+2*50 |
98.2*21.6 |
5.416 |
7853 |
260 |
0.214 |
3*120+2*70 |
110.6*25.6 |
7.098 |
10201 |
320 |
0.167 |
3*150+2*70 |
119*27.6 |
8.355 |
12039 |
385 |
0.134 |
3*185+2*95 |
135.8*30.8 |
10.539 |
15197 |
430 |
0.11 |
3*240+2*120 |
149.7*35.5 |
13.517 |
19585 |
535 |
0.0833 |
Cable Structure
1. Conductor: Oxygen free copper/tinned copper/others, with VDE0295 class 6 standard
2. Insulation: PUR/PE/NBR/PVC…etc optional
3. Filling: tensile filling
4. Shielding: foil shield/copper braided…etc
5. Inner sheath: PUR/PE/NBR/PVC…etc optional
6. Torsion resistant layer: 24P Kevlar braided mesh, which can keep the cable core stable
7. Sheath: high standard PUR/PVC/NBR…etc material
Electrical Performance
Voltage: 0.6/1kv customized
Test Voltage: 3.5kv/5min (AC)
Bending Radius & Temperature Range
Fixed Installation:5 * cable outer diameter
Mobile Installation:6-10 * cable outer diameter
Fixed Installation:– 40 ℃ ~ 125℃
Mobile Installation:– 30 ℃ ~ 90 ℃