TSFLCGEWOEU Medium voltage flat reeling cable
Construction
Conductor: Extra fine bare copper conductor class 6 VDE 0295
Insulation: Special rubber compound based on NBR
Reinforce: Protective earth conductor Individually braid of tinned copper wires
Core: Fiber optics / control cores
Advantages: Outer sheath PUR resistant to tearing, notching and abrasion
Technical Date
Specification(mm2) |
Overall diameter(mm) |
Approx weight(kg/m) |
Tensile Load(N) |
Current at 30℃(A) |
Max. resistance of the Current at 30℃(Ω/KW) |
Voltagedrop per 100m(V) |
3*35+1*16+12FO |
69.2*15.9 |
2.210 |
2057 |
155 |
0.576 |
17.86 |
3*50+1*25+12FO |
82.7*18.5 |
3.111 |
2973 |
175 |
0.401 |
14.04 |
3*70+1*35+12FO |
92.6*20.6 |
4.053 |
4165 |
220 |
0.283 |
12.45 |
3*95+1*50+12FO |
108*22.7 |
5.349 |
5695 |
260 |
0.214 |
11.13 |
3*120+1*70+12FO |
121.7*26.9 |
7.015 |
7310 |
320 |
0.167 |
10.69 |
3*150+1*70+12FO |
130.9*29 |
8.342 |
8842 |
385 |
0.134 |
10.32 |
3*185+1*95+12FO |
149.4*32.3 |
10.476 |
11049 |
430 |
0.11 |
9.46 |
3*240+1*120+12FO |
164.7*37.3 |
13.460 |
14281 |
535 |
0.0833 |
8.91 |
3*35+2*16+12FO |
80.5*16 |
2.547 |
2329 |
155 |
0.576 |
17.86 |
3*50+2*25+12FO |
94*18.5 |
3.547 |
3398 |
175 |
0.401 |
14.04 |
3*70+2*35+12FO |
104.8*20.6 |
4.610 |
4760 |
220 |
0.283 |
12.45 |
3*95+2*50+12FO |
121.9*22.7 |
6.087 |
6544 |
260 |
0.214 |
11.13 |
3*120+2*70+12FO |
134.8*26.9 |
7.933 |
8500 |
320 |
0.167 |
10.69 |
3*150+2*70+12FO |
142.9*29 |
9.254 |
10032 |
385 |
0.134 |
10.32 |
3*185+2*95+12FO |
162.8*32.3 |
11.667 |
12664 |
430 |
0.11 |
9.46 |
3*240+2*120+12FO |
177.5*37.3 |
14.876 |
16321 |
535 |
0.0833 |
8.91 |
Specification(mm2) |
Overall diameter(mm) |
Approx weight(kg/m) |
Tensile Load(N) |
Current at 30℃(A) |
Max. resistance of the Current at 30℃(Ω/KW) |
Voltagedrop per 100m(V) |
3*35+12*2.5+12FO |
88*16 |
2.579 |
2294 |
155 |
0.576 |
17.86 |
3*50+12*2.5+12FO |
97*18.5 |
3.362 |
3058 |
175 |
0.401 |
14.04 |
3*70+12*2.5+12FO |
93.3*20.6 |
3.909 |
4079 |
220 |
0.283 |
12.45 |
3*95+12*2.5+12FO |
102.5*22.7 |
4.914 |
5354 |
260 |
0.214 |
11.13 |
3*120+12*2.5+12FO |
112.9*26.9 |
6.299 |
6629 |
320 |
0.167 |
10.69 |
3*150+16*2.5+12FO |
123.4*29 |
7.695 |
8161 |
385 |
0.134 |
10.32 |
3*185+19*2.5+12FO |
140.2*32.3 |
9.540 |
9943 |
430 |
0.11 |
9.46 |
3*240+24*2.5+12FO |
153.3*37.3 |
12.284 |
12750 |
535 |
0.0833 |
8.91 |
Technical Info
Working voltage: 3.6/6KV
Test Voltage: 12.5 kV AC (5 Min.)
Working temperature: Fixed:-50-125℃ Remove: -30-125℃
Bending radius: Fixed: 6*thickness of cableFlexing: 10* thickness of cable
description2